Introduction | |
---|---|
The PDUMNH32HVAT 7.7kW Single-Phase 200-240V Monitored Automatic Transfer Switch / ATS PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and has one IEC 309 32A Blue outlet for connecting a single device or an additional 230V multi-outlet PDU with IEC 309 32A Blue plug, such as Tripp Lite’s PDUMV32HV. Dual 10-ft. (3.05 m) input cords, each with IEC 309 32A Blue input plug, connect to any two separate primary and secondary input power sources, including out-of-phase input sources. The PDU constantly evaluates the power quality of both inputs. To ensure connected equipment remains powered, dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds if the primary source fails or becomes unstable. Built-in LX Platform network management interface allows remote access to the PDU for power monitoring, configuration, control and to receive user-configurable notifications. The Java-free LX Platform HTML5-based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. Provides real-time load/current data with billing-grade accuracy (±1 percent). It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separate) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. Primary and Secondary Inputs for Power Redundancy Enables redundant power configurations for network devices with a single input cord or other non-redundant power supply configuration Two IEC 309 32A Blue (2P+E) inputs, each with 10-ft. (3.05 m) cord, connect to separate primary and secondary input power sources Any two input power sources are supported for primary and secondary inputs, including out-of-phase power sources Built-In IEC 309 32A Blue Outlet Power a single 32A plug-in device or multiple network devices through a connected 32A 200-240V multi-outlet PDU, such as Tripp Lite's PDUMV32HV metered PDU input (sold separately) Automatic Transfer Switching Dynamic solid-state (TRIAC) automatic transfer switching Switches to secondary power source if primary source fails or becomes unstable 1-5 ms transfer time ensures uninterrupted operation of connected equipment Built-in processor monitors power sources and prevents switching if secondary source is unavailable or of lower quality than primary source Touchscreen LCD Reports input status for primary and secondary power sources, power availability, line voltage, frequency, amps, kilowatts and power factor Advanced Network Monitoring Pre-installed WEBCARDLX with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities PADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations Broad Communications Compatibility Java-free LX Platform HTML5-based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH Supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. 10/100 Mbps auto-sensing for communication with 10/100 Base-T networks Mounts Horizontally in 1U of Rack Space Compatible with EIA-standard 19 in. 4-post racks and rack enclosures Included PDU4PKIT rail kit adds rear rack-mounting support |
|
Design | |
PDU types | Monitored |
Rack capacity | 1U |
Mounting | Horizontal |
Housing material | Metal |
Product colour | Black |
Display | LCD |
Ports & interfaces | |
AC outlets quantity | 2 AC outlet(s) |
Power plug | IEC309 |
Features | |
Cable length | 3.05 m |
Certification | CE |
Power | |
Nominal input voltage | 200-240 V |
AC input frequency | 50 - 60 Hz |
Maximum current | 32 A |
Nominal output voltage | 230 V |
Maximum power | 7400 W |
Weight & dimensions | |
Width | 430 mm |
Depth | 355.6 mm |
Dimensions (WxDxH) | 430 x 356 x 44 mm |
Height | 43.7 mm |
Weight | 6.85 kg |
Packaging data | |
Package dimensions (WxDxH) | 550 x 525 x 190 mm |
Package weight | 9.8 kg |
Package width | 541 mm |
Package depth | 571.5 mm |
Package height | 182.9 mm |
Operational conditions | |
Operating temperature (T-T) | -15 - 50 °C |
Storage temperature (T-T) | -15 - 60 °C |
Operating relative humidity (H-H) | 5 - 95% |
Operating altitude | 0 - 3000 m |
Technical details | |
Sustainability certificates | RoHS |
Logistics data | |
Country of origin | China |
Products per master (outer) case | 1 pc(s) |
Every effort has been made to ensure the accuracy of all information contained herein. e-nitiative shall not be liable for any changes resulting in wrong product description, tax code and/or price. The shown information (specifications, prices, taxes) should be considered as an indication and can be changed at any moment and without any prior notice.