NetShelter Rack PDU Advanced Switched Metered Outlet 34.6kW 3PH 415V 60A 560P6 42 Outlet

NetShelter Rack PDU Advanced Switched Metered Outlet 34.6kW 3PH 415V 60A 560P6 42 Outlet
Brand: APC
Part Number: APDU10450SM
Stock:
Real time Stock Check

£3,960.68 (Excl VAT)
£4,752.82  (incl. VAT)

APC
Introduction
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server
and/or networking racks. Switched outlets to turn outlets on or off remotely. Outlet and PDU level power
metering for power visibility and notification of potential overload. 4-in-1 combination outlets which can
be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum
outlet density with 42 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or
labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating
phase design whereby each of the 3 phases are organized into small outlet groups which alternate
from top to bottom of the PDU to facilitate better power cord management and promote better load
balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network
Management Card to continue functioning in the event of an AC power loss. No interruption in Network
communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC)
which can be replaced without powering down the PDU or connected devices to minimize downtime
in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full
load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to
enhance and standardize network connectivity across all assets in the data center. A second ethernet
port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or
provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU
Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most
precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor
ports allow for optional sensors (sold separately) to be connected. For data center deployments across
multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to
simplify and standardize deployment.
Design
PDU types Metered
Type Three-phase
Rack capacity 0U
Mounting Vertical
Product colour Black
Ports & interfaces
AC outlets quantity 42 AC outlet(s)
AC outlet types C13 coupler, C15 coupler, C19 coupler, C21 coupler
Features
Cable length 1.8 m
Certification UL 62368-1 CSA C22.2 No 62368-1 FCC part 15 subpart B CE EN 62368-1
Power
Nominal input voltage 200 - 240, 346 - 415 V
AC input frequency 50 - 60 Hz
Maximum current 60 A
Number of phases 3
Weight & dimensions
Width 5.6 mm
Depth 7.5 mm
Height 182.6 mm
Weight 12.7 kg
Packaging data
Package weight 15.7 kg
Package width 132 mm
Package depth 262 mm
Package height 1980 mm
Operational conditions
Operating temperature (T-T) -5 - 60 °C
Storage temperature (T-T) -25 - 65 °C
Operating relative humidity (H-H) 5 - 95%
Storage relative humidity (H-H) 5 - 95%
Operating altitude 0 - 3048 m
Non-operating altitude 0 - 15240 m
Operating temperature (T-T) 23 - 140 °F
No options for this product


Partners

Every effort has been made to ensure the accuracy of all information contained herein. e-nitiative shall not be liable for any changes resulting in wrong product description, tax code and/or price. The shown information (specifications, prices, taxes) should be considered as an indication and can be changed at any moment and without any prior notice.