NetShelter Rack PDU Advanced Metered 34.6kW 3PH 415V 60A 560P6 42 Outlet

NetShelter Rack PDU Advanced Metered 34.6kW 3PH 415V 60A 560P6 42 Outlet
Brand: APC
Part Number: APDU10450ME
Stock:
Real time Stock Check

£2,351.98 (Excl VAT)
£2,822.38  (incl. VAT)

APC
Introduction
APC NetShelter Rack PDU Advanced, Metered, 34.6kW, 3PH, 415V, 60A, 560P6, 42 Outlet
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.
Design
PDU types Switched
Type Single-phase
Rack capacity 0U
Mounting Vertical
Product colour Black
Display LCD
On/off switch N
Ports & interfaces
AC outlets quantity 48 AC outlet(s)
Power plug IEC 60309
AC outlet types C13 coupler, C15 coupler, C19 coupler, C21 coupler
Features
Daisy chain Y
Certification CSA C22.2 No 62368-1, FCC part 15 subpart B, UL 62368-1
Power
Nominal input voltage 415 V
AC input frequency 50/60 Hz
Maximum current 60 A
Nominal output voltage 240 V
Output voltage 240 V
Load capacity 34600 VA
Maximum input current per phase 60 A
Maximum total current draw per phase 48 A
Weight & dimensions
Width 56 mm
Depth 75 mm
Height 1826 mm
Weight 11.7 kg
Packaging data
Package weight 14.7 kg
Package width 262 mm
Package depth 132 mm
Package height 1980 mm
Operational conditions
Operating temperature (T-T) -5 - 60 °C
Storage temperature (T-T) -25 - 65 °C
Operating relative humidity (H-H) 5 - 95%
Storage relative humidity (H-H) 5 - 95%
Operating altitude 0 - 3048 m
Non-operating altitude 0 - 15240 m
No options for this product


Partners

Every effort has been made to ensure the accuracy of all information contained herein. e-nitiative shall not be liable for any changes resulting in wrong product description, tax code and/or price. The shown information (specifications, prices, taxes) should be considered as an indication and can be changed at any moment and without any prior notice.